제품 정보로 건너뛰기
Graph showing transmission versus wavelength with a peak at around 1000 nm.

BP1064-5 대역 통과 필터(CWL=1064nm, FWHM=5nm)

SO3010025

중심 파장(CWL) // FWHM
중심 파장(CWL) // FWHM
CWL=1064nm // FWHM=5nm
광학 밀도 // 최대 투과율(Tpk)
광학 밀도 // 최대 투과율(Tpk)
OD5@200-1800nm // T>90%
SO3010025-d12.5mt
재고 있음
$130.00
할인가  $130.00 정가 

맞춤형 사이즈 문의

결제 방법
  • American Express
  • Apple Pay
  • Discover
  • Google Pay
  • JCB
  • Mastercard
  • Visa
Stock Availability
이 제품을 직접 주문할 수 있습니까?
Custom Size & Mounting

맞춤 사이즈 또는 장착 옵션을 요청할 수 있나요?

Request Raw Data
변환 곡선 또는 스펙트럼 데이터를 요청할 수 있나요?
Shipment & Delivery
배송에는 보통 얼마나 걸리나요?
Payment & Quotation

You can order online, request a quotation, or use bank transfer depending on your purchasing process.

Can I request a quotation before ordering?
  • Yes, formal quotations are available before payment
  • Recommended for company purchases, larger quantities, custom sizes, or special shipping requirements
  • Please send the product link, quantity, destination country, and billing details if available
What online payment methods are available?
  • Credit card
  • Apple Pay
  • Google Pay
Do you support bank transfer?
  • Yes, bank transfer is available
  • We support multi-currency payment through local banking where available
  • Local receiving accounts may include US, UK, Germany, Singapore, and Hong Kong bank accounts
  • For payment in Chinese RMB inside Mainland China, please contact our local partner
  • VAT fapiao may be supported for eligible Mainland China transactions
Do you support company purchase orders?
  • Company purchase orders may be supported after confirmation
  • Please contact us before ordering if your organization requires PO processing, quotation, or invoice matching
Are NET payment terms available? (Pay after received)
  • NET 7 or NET 30 terms may be available for eligible organizations
  • Approval depends on company type, order value, payment history, and internal review
  • Please contact us before ordering if you need NET payment terms
Import, Duties & Customs
수입 관세 및 세관 수수료

이 BP1064-5 대역 통과 필터는 1064nm 주변의 좁은 대역을 전송하고 대역 외 빛을 줄이도록 설계되었습니다. 이 필터는 Nd:YAG 또는 광섬유 레이저를 사용하는 NIR 감지, 머신 비전 및 레이저 다이오드 시스템에 적합합니다. 이 필터는 목표 신호를 분리하고 배경 빛을 줄이며 대비를 개선하는 데 도움이 됩니다.

주요 사양:

  • 파장 / 주요 사양: 1064nm 중심 파장 (CWL)
  • 대역폭 / 전이 사양: 5nm FWHM
  • 투과율 / 차단: T >90%; 200-1800nm에서 OD5 차단
  • 형식 / 맞춤 옵션: 직경 12.5mm ~ 직경 25mm (장착/비장착)로 제공; 요청 시 맞춤형 크기 및 장착 옵션 제공

Spectral Data & AOI Review

Filter curves can shift when the filter is used at an angle.

SyronOptics can review spectral data and selected AOI examples to help check whether a filter fits the actual optical path.

LIDT Reference (1064nm)

Selected 1064nm laser damage test data is available for reference when reviewing similar laser-related filter designs.

Final suitability depends on the actual laser condition, coating design, beam size, and system setup.

Custom Size Cutting

Coated filter plates can often be cut into smaller formats for custom optical assemblies.

For narrow bandpass filters, usable area and size may depend on coating uniformity across the larger piece.

BP1064-5 Bandpass Filter - Raman Spectroscopy

BP1064-5 Bandpass Filter - Raman Spectroscopy

Specifications

  • Part Number: BP1064-5 (Commonly associated with manufacturers like SyronOptics, OptoSigma, or similar precision optics vendors).
  • Center Wavelength (CWL): 1064 nm (Infrared/NIR).
  • Bandwidth (FWHM): 5 nm (Narrow band, allowing only 1064 nm ± 2.5 nm to pass).
  • Transmission (T): >90% (High throughput at the peak wavelength).
  • Blocking: OD5 @ 200–1800 nm.

Applications - Raman Spectroscopy

Used to "clean" the excitation laser line (preventing side-modes) or, less commonly for this specific part, to collect the Rayleigh scattered light (though a notch filter is usually used to block it).

Recommended Light Sources

To utilize this filter effectively, you must use a light source that emits precisely at 1064 nm. A broadband source would be inefficient as the filter would reject >99% of the light.

  • Nd:YAG Lasers: The most common source. 1064 nm is the primary fundamental emission line of Neodymium-doped Yttrium Aluminum Garnet lasers.
  • Yb-Doped Fiber Lasers: Ytterbium fiber lasers can be tuned or designed to emit at 1064 nm and are often used in industrial engraving and marking.
  • Nd:YVO4 Lasers: Another solid-state crystal (Yttrium Orthovanadate) that emits at 1064 nm, often used for stable, continuous-wave applications.
  • 1064 nm LEDs / SLEDs: Super-luminescent Diodes (SLEDs) or specific NIR LEDs can be used for lower-power imaging applications, provided their spectral output overlaps significantly with the 5 nm passband.
BP1064-5 Bandpass Filter - Biomedical Imaging

BP1064-5 Bandpass Filter - Biomedical Imaging

Specifications

  • Part Number: BP1064-5 (Commonly associated with manufacturers like SyronOptics, OptoSigma, or similar precision optics vendors).
  • Center Wavelength (CWL): 1064 nm (Infrared/NIR).
  • Bandwidth (FWHM): 5 nm (Narrow band, allowing only 1064 nm ± 2.5 nm to pass).
  • Transmission (T): >90% (High throughput at the peak wavelength).
  • Blocking: OD5 @ 200–1800 nm.

Application - Biomedical Imaging

For photoacoustic imaging or fluorescence microscopy where 1064 nm is the excitation wavelength, and deep blocking of other wavelengths is required to protect the sample or detector.

Recommended Light Sources

  • For Photoacoustic Imaging (PAI) - Q-Switched (Pulsed) Nd:YAG Laser

Why: Photoacoustic imaging relies on the photoacoustic effect, where light is absorbed and converted into sound waves via rapid thermal expansion. This requires high-energy, nanosecond pulses (typically 5–10 ns pulse width) which only a Q-switched laser can provide. A continuous wave (CW) source would simply heat the sample slowly without generating the acoustic pressure wave needed for imaging.

  • For Fluorescence Microscopy (NIR-II / SWIR) - Continuous Wave (CW) or Mode-Locked Nd:YAG / Fiber Laser

Why: Fluorescence typically requires a steady stream of photons to continuously excite the fluorophores (dyes or nanoparticles). A CW Nd:YAG or an Yb-doped Fiber Laser provides the stable, high-intensity illumination needed to excite NIR-II probes (like Ag₂S quantum dots or organic dyes).

유사 1064nm 대역 통과 필터

제품 FAQ

What is the difference between unmounted, mounted, and threaded filter options?

크기 옵션의 경우, 비장착 필터와 장착 필터는 다른 크기 참조를 사용합니다.

비장착 필터
  • 표시된 크기는 실제 필터 크기를 나타냅니다.
  • 예: 12.5mm 비장착은 필터가 직경 12.5mm임을 의미합니다.
장착 필터
  • 표시된 크기는 일반적으로 마운트의 외부 크기를 나타냅니다.
  • 내부 필터는 일반적으로 마운트보다 작습니다.
  • 예: 12.5mm 장착은 마운트 외부가 12.5mm인 반면, 내부 필터는 약간 더 작음을 의미합니다.
  • 내부 필터는 일반적으로 장착 외부 직경보다 약 1–1.5mm 작습니다.
마운트 유형
  • 장착이 자동으로 나사산을 의미하지는 않습니다.
  • 장착으로만 표시된 경우, 일반적으로 매끄럽고 나사산이 없는 마운트를 의미합니다.
  • 나사산 마운트는 M25.5 × 0.5mm 또는 SM1과 같은 나사산 표준을 명시해야 합니다.
참고
  • 시스템이 외경, 유효 구경, 두께 또는 나사산 표준에 대한 엄격한 요구 사항이 있는 경우, 주문 전에 확인하십시오.

광학 필터 두께가 어떻게 되나요?

필터의 두께는 필터가 마운트되지 않은 상태로 제공되는지 아니면 마운트된 상태로 제공되는지에 따라 달라집니다.

마운트되지 않은 필터
  • 일반적으로 0.5mm~2mm
  • 일반적인 두께: 0.5mm, 1.1mm, 1.5mm
  • 그 외의 경우 약 0.3mm~3mm 범위일 수 있습니다.
  • 두께는 기판, 코팅 설계 또는 고객 요구 사항에 따라 달라질 수 있습니다.
마운트된 필터
  • 총 외부 두께는 마운트 구조에 따라 달라집니다.
  • 나사산이 없는 마운트: 일반적으로 약 3.5mm 또는 6mm
  • 미터 나사산 마운트: 일반적으로 약 6.5mm~7.5mm
참고
  • 시스템에 엄격한 두께 제한이 있는 경우 주문하기 전에 필요한 두께를 확인하십시오.

필터는 마운트 내부에 어떻게 고정되어 있나요?

고정 방식은 마운트의 나사산 유무에 따라 달라집니다.

나사산 없는 마운트
  • 필터는 일반적으로 접착제로 고정됩니다.
  • 필터는 조립 후 마운트 내부에 고정됩니다.
  • 필터는 일반적으로 장착 후 분리할 수 없습니다.
나사산 있는 마운트
  • 필터는 일반적으로 고정 링으로 고정됩니다.
  • 접착제는 일반적으로 필요하지 않습니다.
  • 필터는 일반적으로 나중에 제거하거나 교체할 수 있습니다.
참고
  • 필터 분리가 필요한 경우, 주문 전에 고정 링이 있는 나사산 마운트를 요청하십시오.

이 필터를 비정상 입사각에서 사용할 수 있습니까?

예, 하지만 필터를 법선 입사각이 아닌 다른 각도에서 사용할 경우 스펙트럼이 이동할 수 있습니다.

협대역 통과 필터
  • 10nm FWHM 부근: 0-5°와 같은 작은 각도는 일반적으로 영향이 제한적입니다.
  • 10-15°에서는 파장 이동이 눈에 띄게 나타날 수 있습니다.
  • 정밀한 스펙트럼 시스템은 주문 전에 AOI를 신중하게 확인해야 합니다.
광대역 통과 필터
  • 50-100nm FWHM 부근: 일반적으로 각도 변화에 더 잘 견딥니다.
  • 15-20°에서도 일부 시스템에서는 여전히 허용될 수 있습니다.
  • 최종 적합성은 필요한 통과 대역과 차단 범위에 따라 달라집니다.
참고
  • 비법선 입사는 편광 관련 효과를 유발할 수도 있습니다.
  • 시스템이 더 큰 AOI, 편광 또는 엄격한 파장 허용 오차를 사용하는 경우 주문 전에 확인하시기 바랍니다.

필터를 다른 입사각에서 테스트해 볼 수 있나요?

네. 선택된 각도에서 AOI(입사각) 테스트를 제공할 수 있습니다.

AOI 테스트 옵션
  • 일반적인 테스트 각도: 5°, 10°, 15°, 20°, 30°
  • 비정상 입사(non-normal incidence) 시 파장 변화를 검토하는 데 사용
  • 레이저, 이미징 또는 각도에 민감한 광학 시스템에 적합
비용
  • 각도당 USD 35
  • 최소: 요청당 2개 각도
참고
  • AOI 테스트는 주문 전에 요청할 수 있습니다.
  • 이를 통해 시스템 호환성을 확인하기 전에 측정된 성능을 검토할 수 있습니다.

어떤 필터가 제 시스템에 맞는지 확실하지 않으면 어떻게 해야 하나요?

확실하지 않다면 자체 시스템에서 샘플을 테스트하는 것이 적합성을 확인하는 가장 좋은 방법입니다.

샘플 테스트
  • 자격이 있는 회사, 연구소, 대학 또는 연구 그룹 고객에게 제공
  • 일반적으로 미화 150달러 미만의 제품 또는 주문에 적용됩니다.
  • 먼저 테스트한 후 필터가 시스템에 적합한 경우에만 비용을 지불할 수 있습니다.
테스트 후 반품
  • 필터가 적합하지 않은 경우 테스트 후 반품할 수 있습니다.
  • 반품 승인은 제품 상태 및 검토에 따라 달라집니다.
  • 맞춤형, 개조된, 손상된 또는 오염된 제품은 해당되지 않을 수 있습니다.
참고
  • 샘플 테스트가 가능한지 확인하려면 주문 전에 당사에 문의하십시오.

이 필터 확인에 도움이 필요하신가요?

기존 부품을 교체하시거나 새 시스템을 구축하시는 경우, 다음 정보를 보내주십시오:

- 원래 부품 번호 또는 목표 사양
- 필요한 크기 및 수량
- 적용 분야 또는 시스템 목표

저희가 제품 적합성을 확인해 드리거나 재고/맞춤형 대안을 제안해 드리겠습니다.

제품 적합성 확인