735nm Bandpass Filter

735nm bandpass filters are designed to transmit a selected far-red to near-infrared (NIR) wavelength band centered near 735nm while reducing unwanted out-of-band light.

Applications:

  • Far-red and near-infrared fluorescence emission collection
  • Red-edge band detection in agricultural remote sensing and vegetation analysis
  • NIR LED source cleanup for illumination and specialized optical measurement systems
  • Detector-side 735nm signal isolation before cameras, photodiodes, PMTs, or spectrometers
  • Optical measurement setups where the target signal is near 735nm

Bandwidth options:

  • 10nm FWHM for tight 735nm signal isolation and maximum background noise rejection
  • 20nm FWHM for balanced signal transmission and out-of-band background reduction
  • 40nm and 50nm FWHM for broader emission collection, higher signal levels, or accommodating angular shifts

Get Product Recommendation

735nm Bandpass Filter
Skip to results list

Filters

8 items

Active filters:

Filter

Active filters:

US7119960B2 - Hard coated optical filters

US7119960B2 - Hard coated optical filters

Context: This patent describes the fabrication of high-performance, multi-cavity optical filters using sputtering technology, primarily for fluorescence microscopy.

Usage of Filter: The 735 nm band is used as one specific transmission channel within a "multiband" (e.g., penta-band) interference filter.

Function: It selectively transmits a narrow band of Near-Infrared (NIR) light centered at 735 nm while simultaneously blocking adjacent wavelengths and transmitting other visible bands (like blue, green, and red) on the same substrate.

Result: This achieves high-speed, multi-color imaging without moving parts, allowing researchers to visualize NIR fluorophores (like Cy7) simultaneously with visible markers (like GFP/RFP) on a single image sensor.

US8918156B2 - Fluorescence imaging system and method

US8918156B2 - Fluorescence imaging system and method

Context: This patent details a medical imaging system used during surgery to visualize tissue perfusion and anatomy using fluorescent dyes.

Usage of Filter: The bandpass filter is utilized as an excitation filter placed in front of the illumination source (LED or Laser).

Function: It cleans the light source output, restricting it to a precise 735 nm range to efficiently excite a specific fluorophore (such as a methylene blue derivative or NIR dye) while blocking any "tail" energy that might overlap with the detection range.

Result: This achieves a high Signal-to-Noise Ratio (SNR) in the final image, ensuring that the camera detects only the glowing tissue and not the reflected light from the illuminator.

Need Help Choosing a Product?

Share your requirement of spectral or your application goal.We will review and provide product recommendation to you.

Get Product Recommendations