Collection: 660nm Bandpass Filter

660nm light is a red wavelength with strong tissue penetration, positioned at the boundary between visible and near-infrared spectra, offering both photochemical activity and biocompatibility.

  • Application 1: In biomedical phototherapy, 660nm bandpass filters precisely isolate this wavelength for low-level laser treatments, such as stimulating skin collagen production or enhancing mitochondrial energy metabolism.
  • Application 2: For plant growth monitoring, these filters eliminate ambient light interference, allowing only 660nm light to measure chlorophyll fluorescence parameters in leaves, which helps assess photosynthetic efficiency.
  • Application 3: Within fluorescence imaging systems, 660nm bandpass filters work with specific fluorescent markers to block excitation light noise, enabling clear capture of 660nm fluorescent signals for high-contrast biological sample imaging.

660nm Filter Selection Guide: Configuration Logic for Typical Applications

I. Filter Configuration for Fluorescence Imaging Systems

In biomedical fluorescence detection, 660nm filters play a critical role in separating specific fluorescent signals from background noise. Taking the Cy5 dye as an example—with an excitation peak at 649nm and emission peak at 670nm—the following configurations are essential for high-signal-to-noise ratio (SNR) imaging:

1. Dichroic Mirror

  • Central Wavelength: 660nm
  • Bandwidth: 10–20nm
  • Reflectance: ≥95% (640–660nm)
  • Transmittance: ≥90% (670–700nm)
  • Function: Efficiently reflects excitation light while transmitting emission light to eliminate optical path interference

2. Emission Filter

  • Central Wavelength: 660nm
  • Bandwidth: 15–25nm
  • Peak Transmittance: ≥85%
  • Optical Density (OD): ≥4 (350–650nm and 700–1100nm)
  • Function: Precisely captures Cy5 emission spectra while suppressing residual excitation light and autofluorescence

Selection Logic

  • Bandwidth Control: The Cy5 emission spectrum has a half-width of ~20nm, requiring filter bandwidth to cover 660±10nm for complete signal acquisition. Excessively wide bandwidth introduces adjacent band interference, while overly narrow bandwidth causes signal loss.
  • OD Requirement: OD≥4 reduces background light intensity to <0.01%, significantly enhancing imaging contrast. For example, in confocal microscopy, this blocks 99.99% of non-target wavelength signals.
  • Optical Material: Quartz substrates with ion-assisted coating minimize temperature drift (≤0.05nm/℃), ideal for long-term dynamic imaging.

II. Filter Configuration for Laser Communication and Ranging

In free-space optical communication (FSO) and laser ranging systems, 660nm filters are used to suppress ambient light interference and improve signal purity. Typical configurations include:

1. Narrowband Bandpass Filter

  • Central Wavelength: 660nm
  • Bandwidth: 5–10nm (≤1nm for high-precision scenarios)
  • Peak Transmittance: ≥90%
  • Optical Density (OD): ≥5 (350–650nm and 670–1100nm)
  • Function: Isolates laser signals from background radiation such as sunlight and artificial light

2. Anti-Reflective Coating

  • Reflectance: ≤0.2%
  • Effect: Reduces optical path energy loss, preventing signal attenuation >15dB in long-distance communication (e.g., >1km)

Selection Logic

  • Bandwidth Optimization: Laser diodes typically have a linewidth of 0.1–0.3nm, requiring filter bandwidth ≤5nm for high signal selectivity. A 0.5nm bandwidth filter, for instance, can reduce bit error rate to <10⁻⁹ in UAV communication.
  • OD Requirement: OD≥5 suppresses background light to <0.0001%, ensuring SNR≥20dB under strong sunlight—critical for outdoor laser rangefinders to maintain measurement error within ±1cm.
  • Mechanical Stability: Metal-encapsulated filter assemblies withstand temperature ranges of -40℃ to 85℃, suitable for harsh environments like automotive and aerospace applications.

III. Key Parameter Comparison and Scenario Adaptation

Core Parameter Comparison

  • Central Wavelength Accuracy

- Fluorescence Imaging: ±1nm

- Laser Systems: ±0.5nm

  • Bandwidth (FWHM)

- Fluorescence Imaging: 15–25nm

- Laser Systems: 5–10nm (≤1nm for high-precision)

  • Peak Transmittance

- Fluorescence Imaging: ≥85%

- Laser Systems: ≥90%

  • Optical Density

- Fluorescence Imaging: OD≥4 (350–650nm)

- Laser Systems: OD≥5 (350–650nm)

  • Substrate Material

- Fluorescence Imaging: Quartz or K9 glass

- Laser Systems: Fused silica or sapphire

  • Environmental Adaptability

- Fluorescence Imaging: Constant-temperature laboratory environments

- Laser Systems: Wide temperature range (-40℃ to 85℃)

Application Decision Guide

  1. Biomedical Detection: Prioritize 20nm bandwidth and OD4 filters to ensure fluorescent signal integrity.
  2. Short-Distance Communication (<500m): Use 10nm bandwidth filters to balance cost and performance.
  3. High-Precision Ranging (e.g., Industrial Inspection): Select 1nm bandwidth, OD5 ultra-narrowband filters with temperature control modules to achieve wavelength stability of ±0.1nm.

By following this configuration logic, users can precisely match filter parameters to application requirements, achieving optimal balance between interference suppression, SNR enhancement, and system stability.

Need Customization?