Skip to product information
1 of 2

BP370-10 Bandpass Filter(CWL=370nm,FWHM=10nm)

BP370-10 Bandpass Filter(CWL=370nm,FWHM=10nm)

PN:SO3010089

Regular price $60.00 USD
Regular price Sale price $60.00 USD
Sale Sold out
Shipping calculated at checkout.
Center Wavelength (CWL) // FWHM
Optical Density // Peak Transmission (Tpk)
Dimension

Deep UV Precision Filter - BP370-10

Unlock the power of deep UV spectroscopy with our BP370-10 bandpass filter, meticulously engineered for applications demanding exceptional wavelength precision at 370nm. This high-performance filter combines a narrow 10nm full width at half maximum (FWHM) with superior optical density blocking, making it the ideal choice for critical deep UV measurements and analysis.

Superior Specifications:

  • Center Wavelength: 370nm - Optimized for deep UV applications
  • Ultra-Narrow Bandwidth: 10nm FWHM for maximum spectral selectivity
  • High Optical Density: OD3+ blocking for exceptional out-of-band rejection
  • Precision Engineering: Tight wavelength tolerances ensure consistent performance
  • Durable Construction: Built to withstand demanding laboratory environments

Critical Applications:

Essential for deep UV fluorescence microscopy, protein analysis, DNA/RNA quantification, and advanced spectroscopic techniques. The 370nm wavelength is particularly valuable for DAPI excitation, tryptophan fluorescence studies, and applications requiring precise deep UV wavelength isolation with minimal spectral interference.

Technical Advantages:

The BP370-10's narrow 10nm passband delivers unmatched spectral purity in the challenging deep UV region, where precise wavelength control is crucial for accurate measurements. This exceptional selectivity eliminates unwanted background fluorescence and ensures reliable, reproducible results in demanding analytical applications.

Research Excellence:

Widely adopted in life sciences research, pharmaceutical analysis, environmental monitoring, and quality control laboratories. The deep UV range at 370nm is critical for studying aromatic amino acids, nucleic acid interactions, and UV-induced photochemical processes requiring high spectral resolution.

SyronOptics Precision:

Each BP370-10 filter undergoes comprehensive optical testing to verify precise center wavelength accuracy, consistent transmission characteristics, and reliable blocking performance. Our advanced manufacturing ensures the exceptional quality your most demanding deep UV applications require.

Transmission & OD Data

The transmission curve is typical. Actual data may vary from lot to lot, you can request the raw Transmission and OD data from us.

Copy the link of the product page and send email to shop@syronoptics.com to get raw data.

Shipment & Delivery

For stocked products, shipment will usually be made within 5 working days after order.

For customized products, shipment will usually be made within 4-8 weeks after order.

Return & Refund

Stocked Product are eligible to return within 7 days after receiving.

A flat rate of 35$ will be charged for returning.

Custom Sizing

Custom sizing is available for dimension under 60x60mm. Without mounting the thickness will generally ranging from 0.5-3mm.

For bigger size, contact shop@syronoptics.com for details.

Optical dicing refers to precision cutting processes used to segment optical materials, particularly those with specialized coatings, into smaller functional components while maintaining their structural and optical integrity. In the context of optical coating flats (flat substrates like glass, fused silica, or semiconductors coated with anti-reflective, dielectric, or other optical layers), dicing ensures these coated substrates meet exact dimensional requirements for applications in photonics, lasers, sensors, and semiconductor devices.

Methods

  • Saw Dicing: Diamond-coated blades for clean cuts with minimal chipping.
  • Laser Dicing: Non-contact ablation for delicate or brittle materials, reducing mechanical stress.
  • Plasma Dicing: Dry etching for ultra-fine features, ideal for advanced semiconductor wafers.

Price

Dicing Service will generally cost from $50 to $125 per piece. Depending on the accuracy and size you are requesting.

Packaging

If you need generic packaging, please leave "Generic" in the note when placing order.

In such case:

  • No Branding information in Packaging Materials
  • All Documentation will be generic
  • We will send image of the parcel to you before fulfilling shipment
  • You can use your document template for the shipment.

Feel free to contact shop@syronoptics.com for details.

Payment

Payment could be done online with Credit Card, Apple Pay, Google Pay, Wechat Pay and Alipay

For amount under $200 you can request to make payment within 7days after receiving the order.

SKU:

View full details

Fequently Asked Questions

What are the Thickness of the Optical Filters?

For Mounted Optics:

  • 6mm (by Default)
  • 3.5mm (Specified in Order Note)

For Unmounted Optics:

  • 0.5mm
  • 1.1mm
  • 2mm

(most of the unmounted optics are having thickness of 1.1mm ~ 2mm)

What is the difference between mountings?

Unmounted:

  • a bare glass optical filter

Mounted:

  • Smooth Mount for protection of the optics. No thread is there on the mount.

Metric Mount:

  • Start with M as prefix, usually seens as M25.5x0.5mm. Mostly used as camera filters

Imperial Mount (Usually Thorlabs):

  • Start with SM as prefix, usually seen SM1, SM05 etc... Mostly used in Optical system. (You will have a SM external thread to connecting to other objects)

C-Mount:

  • Very frequently used mounting. C-Mount is 1‘’-32TPI. And it is not the same thing as SM1, or M25.5x0.5mm.
  • Our filters can be cut to match the mounting on the list. Please contact us for getting quotation.

Need any help?

Contact form

Other Wavelength