BP590-50 Bandpass Filter(CWL=590nm,FWHM=50nm)
BP590-50 Bandpass Filter(CWL=590nm,FWHM=50nm)
PN:SO3010329
Couldn't load pickup availability
BP590-50 Bandpass Filter - Broad Bandwidth Yellow-Orange Performance
The BP590-50 bandpass filter is engineered for applications demanding broad spectral coverage in the yellow-orange region. With a 590nm center wavelength and broad 50nm FWHM bandwidth, this filter delivers exceptional light throughput while maintaining OD6 blocking of unwanted wavelengths, making it ideal for fluorescence microscopy, biological imaging, and multi-color detection systems.
Key Features
- Center Wavelength (CWL): 590nm - optimized for yellow-orange light applications
- Broad Bandwidth: 50nm FWHM for maximum light collection and signal strength
- Exceptional Blocking: OD6 optical density ensures 1,000,000:1 rejection of unwanted wavelengths
- High Transmission: Optimized coatings maximize throughput across the passband
- Premium Quality: Hard-coated surfaces for long-term durability and stability
Applications
Perfect for applications requiring broad yellow-orange light transmission including:
- Fluorescence microscopy with red-shifted fluorophores (Texas Red, mCherry, DsRed)
- Biological imaging and live-cell microscopy
- Flow cytometry and multi-color cell analysis
- Confocal microscopy and multi-photon imaging
- LED-based illumination and imaging systems
- Machine vision and color separation applications
- Spectroscopy and photometric analysis
- Bioluminescence and chemiluminescence detection
Technical Excellence
The 590nm wavelength sits at a critical position in the visible spectrum, bridging the gap between yellow and orange light. Our BP590-50 filter's broad 50nm bandwidth (spanning approximately 565-615nm) maximizes light collection efficiency, providing superior signal strength for fluorescence applications while maintaining exceptional spectral selectivity with OD6 (1,000,000:1) blocking performance.
This broad bandwidth design is particularly advantageous for fluorescence microscopy applications involving red-shifted fluorescent proteins and dyes. The wide passband efficiently captures the full emission spectrum of fluorophores like Texas Red, mCherry, and DsRed, maximizing signal-to-noise ratios and reducing exposure times in live-cell imaging experiments.
The OD6 blocking performance ensures that even weak fluorescence signals can be detected without interference from excitation light or emissions from other fluorophores in multi-color imaging experiments. This exceptional out-of-band rejection is critical for sensitive biological imaging applications where signal levels may be limited by photobleaching or phototoxicity concerns.
Manufactured using advanced ion-beam sputtering technology, the BP590-50 delivers consistent performance across the entire aperture with minimal transmission variation. The hard-coated surfaces ensure durability in demanding laboratory environments, maintaining optical quality through years of continuous use in fluorescence microscopy systems.
The 50nm bandwidth also provides excellent compatibility with LED-based illumination sources, which typically exhibit broader emission spectra than laser sources. This makes the filter ideal for modern LED-based microscopy systems and machine vision applications where broad spectral coverage is essential for maximum light efficiency.
Whether you're conducting fluorescence imaging with red fluorescent proteins, performing multi-color flow cytometry, developing LED-based optical systems, or working with biological samples, the BP590-50 provides the perfect balance of broad spectral coverage, maximum light throughput, and exceptional blocking performance. Trust SyronOptics for optical components that deliver research-grade performance for demanding biological imaging applications.
Transmission & OD Data
Transmission & OD Data
The transmission curve is typical. Actual data may vary from lot to lot, you can request the raw Transmission and OD data from us.
Copy the link of the product page and send email to shop@syronoptics.com to get raw data.
Shipment & Delivery
Shipment & Delivery
For stocked products, shipment will usually be made within 5 working days after order.
For customized products, shipment will usually be made within 4-8 weeks after order.
Return & Refund
Return & Refund
Stocked Product are eligible to return within 7 days after receiving.
A flat rate of 35$ will be charged for returning.
Custom Sizing
Custom Sizing
Custom sizing is available for dimension under 60x60mm. Without mounting the thickness will generally ranging from 0.5-3mm.
For bigger size, contact shop@syronoptics.com for details.
Optical dicing refers to precision cutting processes used to segment optical materials, particularly those with specialized coatings, into smaller functional components while maintaining their structural and optical integrity. In the context of optical coating flats (flat substrates like glass, fused silica, or semiconductors coated with anti-reflective, dielectric, or other optical layers), dicing ensures these coated substrates meet exact dimensional requirements for applications in photonics, lasers, sensors, and semiconductor devices.
Methods
- Saw Dicing: Diamond-coated blades for clean cuts with minimal chipping.
- Laser Dicing: Non-contact ablation for delicate or brittle materials, reducing mechanical stress.
- Plasma Dicing: Dry etching for ultra-fine features, ideal for advanced semiconductor wafers.
Price
Dicing Service will generally cost from $50 to $125 per piece. Depending on the accuracy and size you are requesting.
Packaging
Packaging
If you need generic packaging, please leave "Generic" in the note when placing order.
In such case:
- No Branding information in Packaging Materials
- All Documentation will be generic
- We will send image of the parcel to you before fulfilling shipment
- You can use your document template for the shipment.
Feel free to contact shop@syronoptics.com for details.
Payment
Payment
Payment could be done online with Credit Card, Apple Pay, Google Pay, Wechat Pay and Alipay
For amount under $200 you can request to make payment within 7days after receiving the order.
SKU:
View full details

| Part Number | |
|---|---|
PN |
SO3010329
|
| Optical Specification | |
Center Wavelength |
590nm
|
FWHM |
50nm
|
Optical Density |
OD6@200-1200nm
|
Fequently Asked Questions
What are the Thickness of the Optical Filters?
For Mounted Optics:
- 6mm (by Default)
- 3.5mm (Specified in Order Note)
For Unmounted Optics:
- 0.5mm
- 1.1mm
- 2mm
(most of the unmounted optics are having thickness of 1.1mm ~ 2mm)
What is the difference between mountings?
Unmounted:
- a bare glass optical filter
Mounted:
- Smooth Mount for protection of the optics. No thread is there on the mount.
Metric Mount:
- Start with M as prefix, usually seens as M25.5x0.5mm. Mostly used as camera filters
Imperial Mount (Usually Thorlabs):
- Start with SM as prefix, usually seen SM1, SM05 etc... Mostly used in Optical system. (You will have a SM external thread to connecting to other objects)
C-Mount:
- Very frequently used mounting. C-Mount is 1‘’-32TPI. And it is not the same thing as SM1, or M25.5x0.5mm.
Standard Mountings
Camera Mounting List
-
Our filters can be cut to match the mounting on the list. Please contact us for getting quotation.