BP925-365 Bandpass Filter(CWL=925nm,FWHM=365nm)
BP925-365 Bandpass Filter(CWL=925nm,FWHM=365nm)
PN:SO3013272
Couldn't load pickup availability
Wide-Band NIR Bandpass Filter - BP925-365
Engineered for broadband near-infrared applications requiring wide spectral coverage centered at 925nm.
Key Specifications
- Center Wavelength (CWL): 925nm - Optimal for near-infrared applications
- Full Width Half Maximum (FWHM): 365nm - Ultra-wide bandwidth for broad spectral coverage
- Spectral Range: Approximately 742nm to 1107nm (at 50% transmission points)
- High Transmission: Optimized for maximum light throughput across the passband
- Effective Blocking: Superior out-of-band rejection for clean signal isolation
- Multiple Mounting Options: Available in various configurations for system integration
Ideal Applications
Perfect for:
- Broadband NIR spectroscopy and analysis
- Multi-wavelength imaging systems
- Fluorescence applications with wide emission spectra
- Silicon detector optimization (covers peak sensitivity range)
- Biomedical imaging and tissue analysis
- Agricultural and food quality assessment
- Material characterization and sorting
- Environmental monitoring systems
Why Choose SyronOptics BP925-365?
Broadband Performance: Unlike narrow bandpass filters, the BP925-365 provides exceptional coverage across a wide NIR spectrum, making it ideal for applications requiring simultaneous detection of multiple wavelengths or broad spectral features.
Silicon Detector Compatibility: The 742-1107nm range perfectly matches the high-sensitivity region of silicon photodetectors, maximizing signal-to-noise ratio in detection systems.
Versatile Integration: Available in multiple mounting configurations to seamlessly integrate into existing optical systems, from research setups to industrial equipment.
Technical Advantages
- Wide Spectral Coverage: 365nm bandwidth captures broad spectral features and multiple emission lines
- Optimized Transmission: Engineered coating design ensures uniform transmission across the entire passband
- Clean Blocking: Effective rejection of visible and longer NIR wavelengths prevents interference
- Stable Performance: Consistent optical properties across temperature variations
- Low Scatter: High-quality substrates minimize stray light and improve contrast
Application Benefits
For Spectroscopy: Capture multiple absorption or emission features simultaneously, reducing measurement time and improving data quality.
For Imaging: Enable broadband NIR imaging with enhanced contrast and penetration depth for biological and material samples.
For Detection Systems: Maximize the effective quantum efficiency of silicon detectors while blocking unwanted wavelengths.
Essential for researchers, engineers, and system integrators working with broadband NIR applications who need reliable, wide-spectrum optical filtering.
Transmission & OD Data
Transmission & OD Data
The transmission curve is typical. Actual data may vary from lot to lot, you can request the raw Transmission and OD data from us.
Copy the link of the product page and send email to shop@syronoptics.com to get raw data.
Shipment & Delivery
Shipment & Delivery
For stocked products, shipment will usually be made within 5 working days after order.
For customized products, shipment will usually be made within 4-8 weeks after order.
Return & Refund
Return & Refund
Stocked Product are eligible to return within 7 days after receiving.
A flat rate of 35$ will be charged for returning.
Custom Sizing
Custom Sizing
Custom sizing is available for dimension under 60x60mm. Without mounting the thickness will generally ranging from 0.5-3mm.
For bigger size, contact shop@syronoptics.com for details.
Optical dicing refers to precision cutting processes used to segment optical materials, particularly those with specialized coatings, into smaller functional components while maintaining their structural and optical integrity. In the context of optical coating flats (flat substrates like glass, fused silica, or semiconductors coated with anti-reflective, dielectric, or other optical layers), dicing ensures these coated substrates meet exact dimensional requirements for applications in photonics, lasers, sensors, and semiconductor devices.
Methods
- Saw Dicing: Diamond-coated blades for clean cuts with minimal chipping.
- Laser Dicing: Non-contact ablation for delicate or brittle materials, reducing mechanical stress.
- Plasma Dicing: Dry etching for ultra-fine features, ideal for advanced semiconductor wafers.
Price
Dicing Service will generally cost from $50 to $125 per piece. Depending on the accuracy and size you are requesting.
Packaging
Packaging
If you need generic packaging, please leave "Generic" in the note when placing order.
In such case:
- No Branding information in Packaging Materials
- All Documentation will be generic
- We will send image of the parcel to you before fulfilling shipment
- You can use your document template for the shipment.
Feel free to contact shop@syronoptics.com for details.
Payment
Payment
Payment could be done online with Credit Card, Apple Pay, Google Pay, Wechat Pay and Alipay
For amount under $200 you can request to make payment within 7days after receiving the order.
SKU:
View full details

| Part Number | |
|---|---|
PN |
SO3013272
|
| Optical Specification | |
Center Wavelength |
925nm
|
FWHM |
365nm
|
Optical Density |
OD6@200-1800nm
|
Fequently Asked Questions
What are the Thickness of the Optical Filters?
For Mounted Optics:
- 6mm (by Default)
- 3.5mm (Specified in Order Note)
For Unmounted Optics:
- 0.5mm
- 1.1mm
- 2mm
(most of the unmounted optics are having thickness of 1.1mm ~ 2mm)
What is the difference between mountings?
Unmounted:
- a bare glass optical filter
Mounted:
- Smooth Mount for protection of the optics. No thread is there on the mount.
Metric Mount:
- Start with M as prefix, usually seens as M25.5x0.5mm. Mostly used as camera filters
Imperial Mount (Usually Thorlabs):
- Start with SM as prefix, usually seen SM1, SM05 etc... Mostly used in Optical system. (You will have a SM external thread to connecting to other objects)
C-Mount:
- Very frequently used mounting. C-Mount is 1‘’-32TPI. And it is not the same thing as SM1, or M25.5x0.5mm.
Standard Mountings
Camera Mounting List
-
Our filters can be cut to match the mounting on the list. Please contact us for getting quotation.