BP905-10 Bandpass Filter(CWL=905nm,FWHM=10nm)
BP905-10 Bandpass Filter(CWL=905nm,FWHM=10nm)
PN:SO3010683
Couldn't load pickup availability
Precision Near-Infrared Filter - BP905-10
Achieve exceptional near-infrared performance with our BP905-10 bandpass filter, meticulously engineered for precision applications at 905nm. This high-performance filter delivers outstanding spectral selectivity with a narrow 10nm full width at half maximum (FWHM) and superior OD3+ blocking, making it the ideal choice for demanding LiDAR systems and precision NIR applications requiring maximum spectral purity.
Precision Specifications:
- Center Wavelength: 905nm - Optimized for precision near-infrared applications
- Narrow Bandwidth: 10nm FWHM for exceptional spectral selectivity
- Superior Blocking: OD3+ optical density for outstanding out-of-band rejection
- LiDAR Optimized: Specifically designed for LiDAR and remote sensing applications
- Precision Grade: Built for demanding measurement and detection systems
Critical Applications:
Essential for LiDAR remote sensing systems, precision rangefinding, autonomous vehicle sensors, and high-resolution NIR spectroscopy. The 905nm wavelength combined with narrow 10nm bandwidth is particularly valuable for eye-safe laser systems, atmospheric monitoring, and applications requiring precise wavelength discrimination in the near-infrared spectrum.
LiDAR Excellence:
The BP905-10 is specifically optimized for LiDAR applications where precise 905nm wavelength selection is critical for accurate distance measurements and object detection. The narrow bandwidth ensures maximum signal-to-noise ratio while effectively blocking unwanted background radiation that could compromise measurement accuracy.
Remote Sensing Applications:
Widely adopted in advanced remote sensing systems for atmospheric studies, environmental monitoring, and precision mapping applications. The 905nm wavelength provides excellent atmospheric transmission characteristics while the narrow 10nm bandwidth enables precise spectral discrimination for enhanced measurement reliability.
Technical Advantages:
The BP905-10's narrow 10nm passband delivers unmatched spectral purity at 905nm, essential for applications where precise wavelength control directly impacts system performance. This exceptional selectivity eliminates spectral interference and ensures reliable operation in demanding measurement environments.
SyronOptics Precision Engineering:
Each BP905-10 filter undergoes rigorous testing to ensure precise center wavelength accuracy, consistent transmission characteristics, and reliable blocking performance. Our commitment to precision manufacturing ensures your critical LiDAR and remote sensing applications receive the optical performance they demand.
Transmission & OD Data
Transmission & OD Data
The transmission curve is typical. Actual data may vary from lot to lot, you can request the raw Transmission and OD data from us.
Copy the link of the product page and send email to shop@syronoptics.com to get raw data.
Shipment & Delivery
Shipment & Delivery
For stocked products, shipment will usually be made within 5 working days after order.
For customized products, shipment will usually be made within 4-8 weeks after order.
Return & Refund
Return & Refund
Stocked Product are eligible to return within 7 days after receiving.
A flat rate of 35$ will be charged for returning.
Custom Sizing
Custom Sizing
Custom sizing is available for dimension under 60x60mm. Without mounting the thickness will generally ranging from 0.5-3mm.
For bigger size, contact shop@syronoptics.com for details.
Optical dicing refers to precision cutting processes used to segment optical materials, particularly those with specialized coatings, into smaller functional components while maintaining their structural and optical integrity. In the context of optical coating flats (flat substrates like glass, fused silica, or semiconductors coated with anti-reflective, dielectric, or other optical layers), dicing ensures these coated substrates meet exact dimensional requirements for applications in photonics, lasers, sensors, and semiconductor devices.
Methods
- Saw Dicing: Diamond-coated blades for clean cuts with minimal chipping.
- Laser Dicing: Non-contact ablation for delicate or brittle materials, reducing mechanical stress.
- Plasma Dicing: Dry etching for ultra-fine features, ideal for advanced semiconductor wafers.
Price
Dicing Service will generally cost from $50 to $125 per piece. Depending on the accuracy and size you are requesting.
Packaging
Packaging
If you need generic packaging, please leave "Generic" in the note when placing order.
In such case:
- No Branding information in Packaging Materials
- All Documentation will be generic
- We will send image of the parcel to you before fulfilling shipment
- You can use your document template for the shipment.
Feel free to contact shop@syronoptics.com for details.
Payment
Payment
Payment could be done online with Credit Card, Apple Pay, Google Pay, Wechat Pay and Alipay
For amount under $200 you can request to make payment within 7days after receiving the order.
SKU:
View full details

| Part Number | |
|---|---|
PN |
SO3010683
|
| Optical Specification | |
Center Wavelength |
905nm
|
FWHM |
10nm
|
Optical Density |
OD4@200-1200nm
|
Curve Transmission Curve from last batch production.
(Performance may vary from batch to batch)
(Zero Value is not shown in the graph)
(Regular Testing Region from 200-1200nm)
|
|
Fequently Asked Questions
What are the Thickness of the Optical Filters?
For Mounted Optics:
- 6mm (by Default)
- 3.5mm (Specified in Order Note)
For Unmounted Optics:
- 0.5mm
- 1.1mm
- 2mm
(most of the unmounted optics are having thickness of 1.1mm ~ 2mm)
What is the difference between mountings?
Unmounted:
- a bare glass optical filter
Mounted:
- Smooth Mount for protection of the optics. No thread is there on the mount.
Metric Mount:
- Start with M as prefix, usually seens as M25.5x0.5mm. Mostly used as camera filters
Imperial Mount (Usually Thorlabs):
- Start with SM as prefix, usually seen SM1, SM05 etc... Mostly used in Optical system. (You will have a SM external thread to connecting to other objects)
C-Mount:
- Very frequently used mounting. C-Mount is 1‘’-32TPI. And it is not the same thing as SM1, or M25.5x0.5mm.
Standard Mountings
Camera Mounting List
-
Our filters can be cut to match the mounting on the list. Please contact us for getting quotation.